A house buyer's report doesn't include the state of your proprty's electrics
house extension|commercial builder|property maintenance|electrical repair|commercial renovationoffice fit out|shop refurbishment
Shear walls are an important component of the overall seismic reinforcement of buildings, and are of great significance for the overall load and seismic resistance of buildings. So for shear walls, maintenance and reinforcement are also essential. If the method is not applied correctly, it is a hidden danger to the safety of the entire house.

To reinforce shear walls, the steel reinforcement binding method is used, which involves binding and aligning concealed columns to control the binding of wall reinforcement. Before binding, a spacing line should be drawn to indicate the spacing between horizontal bars, and two horizontal bars should be used for positioning. On the horizontal bars, mark the spacing line between vertical bars and tie the remaining vertical bars. It should be noted that the length of vertical steel bars cannot exceed 6 meters, and the length of horizontal steel bars cannot exceed 8 meters. Another important point is to use braces to fix the spacing of the steel bars in order to ensure that the cross-sectional dimensions of the steel bars meet the requirements. After completion, it is necessary to carefully test the verticality of the core tube reinforcement and control the size of the hidden beam.

During the reinforcement process, building reinforcement glue is used. Building reinforcement glue is a specialized adhesive for strengthening building structures and frame reinforcement, which is acid and alkali resistant, aging resistant, and has a service life of up to 50 years. It can effectively maintain shear walls. It has good temperature resistance and can be used in an environment of 135 ° C for a long time. It has good welding resistance and flame retardancy, so even in the event of a fire, it will not easily soften or peel off. Good seismic performance, with almost no shrinkage during the curing process.

Shear wall reinforcement is a very important part of structural reinforcement. If the shear wall is damaged, the safety performance of the entire building will be greatly reduced, and it will be almost impossible to dissipate the force transmission during earthquakes, leading to collapse. The adhesive used in shear wall reinforcement is also very important. It is necessary to use professional building reinforcement adhesive with excellent performance, which is the correct choice for your shear wall reinforcement.
Tagged as: ,
Share this post: